- Out-of-Stock

Reference: 02-008
Brand: Energibutiken, WebIQ AB
Tube surface Sensor, affordable 5 meter 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to the Logger 2020. This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20
Reference: 01-009
Brand: Eastron
Eastron SDM120D MID single phase meter Affordable electricity meter with both flashing diode and pulse output with 1000 imp / kWh. One module wide.
Reference: 04-013
Brand: Energibutiken, WebIQ AB
Cable 3-wire Unshielded cable for connection of temp sensors/modules and/or to use as a bus conductor in the system. Area: 3 x 0.14 mm2Color: GraySelect cable length before you add to shopping cart.
Reference: 01-001
Brand: Eastron
MID certified Threee Phase Energy Meter! MID certified 3-phase electricity meters with both non-resetable counter and resettable trip counter, power meter that shows exactly how many watts that is currently consumed.4 modules wide. For 35 mm DIN rail. Perfect for those who want to monitor the house, cottage, heat pump, or whatever it may be! Need help?...
Reference: 01-004
Brand: Eastron
Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.
Reference: 04-012
Brand: Energibutiken, WebIQ AB
Cable 2X0.14 mm2 Unshielded cable for connection of electricity meter sensors, digital input sensors.Area: 2 x 0.14 mm2Color: Gray Select cable length before adding to cart.
Reference: 25-001
Chint NL210 3-phase earth leakage circuit breaker TYPE BGround fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.
Reference: 02-033
Brand: Energibutiken, WebIQ AB
Hose clamp for fastening Pipe wrap probe Fits Pipe wrap probe Dallas 1 PRO and PT1000 and PT100 Pipe wrap probe. Takes pipes up to 100 mm diameter.
Reference: 02-006
Brand: Energibutiken, WebIQ AB
Tube surface Sensor, affordable 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to Logger 2020. This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20
Reference: 15-001
Brand: Energibutiken, WebIQ AB
Vibration dampers Premium "Soft" A kit that we meticulously evaluated and put together to get the best possible way to de-vibrate air heat pumps. This "soft" kit has slightly softer springs than our "hard" kit, especially designed for those who mount in places that are well protected from harsh winds. Our soft package has hardness 5/3 compared to the hard...
SDM630 Modbus MCT V2 3-phase energy meter. (Non MID)
For use with current transformators (Coils) 50 A and up. We stock 50, 100 and 200 A coils.
Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 3030 datalogger.
SDM630 Modbus 3-phase electricity meter (Non MID)
For use with current transformators (Coils) 50 A and up. We stock 50, 100 and 200 A coils.
With Modbus RTU, pulse output suitable for logging.
Modular device for DIN rail 35mm, width: 4 modules (72.3 mm), the display shows Volts, Watts, Apmeres, Frequecy, Power factor and more.
Order 100A/5A split core coils
Order 200A/5A Split Core Coils
Specifications
5.1 Measured Parameters
The unit can monitor and display three phase four wire (3p4w) supply.
5.1.1 Voltage and Current
Phase to neutral voltages 100 to 289V a.c.
Voltages between phases 173 to 500V a.c.
Percentage total voltage harmonic distortion (THD%) for each phase to N
Percentage voltage THD% between phases
Current THD% for each phase
Power factor and Frequency and Max. Demand
Frequency in Hz
Instantaneous power:
Power 0 to 3600 MW
Reactive Power 0 to 3600 MW
Volt-amps 0 to 3600 MVA
Maximum demanded power since last Demand reset Power factor
Maximum neutral demand current, since the last Demand reset (for three phase supplies only)
Energy Measurements
Imported active energy 0 to 9999999.9 kWh
Exported active energy 0 to 9999999.9 kWh
Imported reactive energy 0 to 9999999.9 kVArh
Exported reactive energy 0 to 999999.99 kVArh
Total active energy 0 to 9999999.9 kWh
Total reactive energy 0 to 9999999.9 kVArh
Measured Inputs
Terminals for cables is 2.5 mm2
Accuracy
Voltage 0·5% of range maximum
Current 0·5% of nominal
Frequency 0·2% of mid-frequency
Power factor 1% of unity (0.01)
Active power (W) ±1% of range maximum
Reactive power (VAr) ±1% of range maximum
Apparent power (VA) ±1% of range maximum
Active energy (Wh) Class 1 IEC 62053-21
Reactive energy (VARh) ±1% of range maximum
Total harmonic distortion 1% up to 31st harmonic
Temperature co-efficient Voltage and current = 0.013%/°C typical
Active energy = 0·018%/°C, typical
Response time to step input 1s, typical, to >99% of final reading, at 50 Hz.
Interfaces for External Monitoring
Three interfaces are provided:
an RS-485 communication channel that can be programmed for Modbus RTU protocol
an relay output indicating real-time measured energy.(configurable)
One fixed pulse output 3200 Imp/kWh
The Modbus configuration (Baud rate etc.) and the pulse relay output assignments (kW/kVArh,
import/export etc.) are configured through the Set-up screens.
Pulse Relay Output
The pulse relay output can be set to generate pulses to represent kWh or kVArh.
Rate can be set to generate 1 pulse per:
0.01 = 10 Wh/VArh
0.1 = 100 Wh/VArh
1 = 1 kWh/kVArh
10 = 10 kWh/kVArh
100 = 100 kWh/kVArh
1000 = 1000 kWh/kWarh
Pulse width 200/100/60 ms.
Relay Rating 240V ac 50mA
RS485 Output for Modbus RTU
For Modbus RTU, the following RS485 communication parameters can be configured from the
Set-up menu:
Baud rate 2400, 4800, ,9600, ,19200, 38400
Parity none/odd/even
Stop bits 1 or 2
RS485 network address nnn – 3-digit number, 1 to 247
Modbus™ Word order Hi/Lo byte order is set automatically to normal or reverse. It cannot
be configured from the set-up menu.
Reference Conditions of Influence Quantities
Influence Quantities are variables that affect measurement errors to a minor degree. Accuracy is
verified under nominal value (within the specified tolerance) of these conditions.
Ambient temperature 23°C ±2°C
Input waveform 50 or 60Hz ±2%
Input waveform Sinusoidal (distortion factor < 0·005)
Auxiliary supply voltage Nominal ±1%
Auxiliary supply frequency Nominal ±1%
Auxiliary supply waveform (if AC) Sinusoidal (distortion factor < 0·05)
Magnetic field of external origin Terrestrial flux
Environment
Operating temperature -25°C to +55°C*
Storage temperature -40°C to +70°C*
Relative humidity 0 to 90%, non-condensing
Altitude Up to 2000m
Warm up time 1 minute
Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Shock 30g in 3 planes
*Maximum operating and storage temperatures are in the context of typical daily and seasonal
variation.
Mechanics
35 mm DIN rail dimensions 72,3 x 100 mm (WxH) per DIN 43880
Mounting DIN rail (DIN 43880)
Sealing IP51
Material Self-extinguishing UL 94 V-0
Volt, Amps, Power, Power factor and more
Reference: 01-018
Brand: Hager
Distribution box for 4 modules, white. For safe installation of relays and / or electricity meters for DIN rail. Dimensions (W X H X D = 110 X 180 X 82 mm)
Reference: 01-012
Brand: Energibutiken, WebIQ AB
Split core Current transformer 200A / 5A Inner diameter for coils are 21 X 32 mm. Fits our three-phase electricity meter SDM630 MCT V2 and the single-phase meters SDM120D CTM and CTMB.Exterior dimensions: Width 87 X Height 105 X Depth 32 mm1 piece (Buy 3 pieces for a three-phase electricity meter)Accuracy 0.5%NOTE! Check cable dimensions. Compare with the...
Reference: 03-015
Brand: Energibutiken, WebIQ AB
Logger 1010 'Logger 1010 is a powerful logger / control unit with a focus on being maximally flexible and easy to use. Support for a plethora of sensors, logging locally and remotely, and alarm possibilities via SMS and e-mail, make the areas of use almost endless.
Reference: 01-040
Current transformer 150A / 5A Inner diameter of the coil is 23 X 24 mm. Fits our electric meters SDM630 MCT V2 and Elmätare 3-fas Carlo Gavazzi EM330-HM1 M-bus MID för mätning med strömspolar. . External dimensions: 45 X 41 X 76 mm NOTE! when buying, choose 1 pc for single-phase, 3 pcs for three-phase electricity meters. Accuracy 0.5%
Reference: 01-058
Openable current coils 200A/5A The current coil fits the following electricity meters SDM630 MCT V2 MID, SDM630 MCT V2 non-MID, SDM120D CT-P, SDM120CTM MID, SDM120CTMB M-bus MID, SDM630 MCT M-bus V2 MID. Inner diameter of the coil is 23 X 23 mm. External dimensions: Width 52 X Height 76 X Depth 42 mm 1 piece (Buy 3 pieces for three-phase electricity...
Reference: 01-062
Split core current transformer 400A / 5A SCT036TS 400/5 A Inner diameter of the coil is 35 mm. Fits our electric meters SDM630 MCT V2 SDM120CTM, SDM120CTMB External dimensions: 49 X 66 X 93 mm Includes 1 pcs (Order 3 pcs for three-phase electricity meters) Accuracy 1%
Reference: 01-030
Distribution box for 13 modules, white. For safe installation of relays and / or electricity meters for DIN rail.
Reference: 01-066
Brand: Carlo Gavazzi
Electricity meter 3-phase Carlo Gavazzi EM340-S1 Electricity meter EM340DINAV23XS1PFB for 3-phase (65A / 400V) with Modbus (RS485). Approved for billing measurement, used for net measurement / production. Small size, easy configuration.
Reference: 01-029
Brand: Eastron
SDM630 MCT M-bus V2 MID 3-phase energy meter. Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, M-bus communication available suitable for our Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.
Reference: 01-074
Distribution box for 4 modules, white with a clear black front cover. . For safe installation of relays and / or electricity meters for DIN rail. W X H X D = 110 X 180 X 82 mm
Reference: 01-027
Brand: Inepro
INEPRO three phase electric meter PRO380 ModbusFor more detailed information on this meter, refer to the MANUAL.featuresThree phase active energy meterConforms and Certified for MID B and D Standard (Can be used for billing purposes)100A online
Reference: 01-040
Current transformer 150A / 5A Inner diameter of the coil is 23 X 24 mm. Fits our electric meters SDM630 MCT V2 and Elmätare 3-fas Carlo Gavazzi EM330-HM1 M-bus MID för mätning med strömspolar. . External dimensions: 45 X 41 X 76 mm NOTE! when buying, choose 1 pc for single-phase, 3 pcs for three-phase electricity meters. Accuracy 0.5%
Reference: 01-004
Brand: Eastron
Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.
Reference: 01-056
Brand: Qubino
Qubino 3-phase Z-Wave Electricity Meter Qubino 3-phase Smart Meter is an extremely versatile and powerful Z-Wave unit for suitable to three-phase conections up to 3 x 65A.
Reference: 01-036
Distribution box for 26 modules, white. For safe installation of relays and / or electricity meters for DIN rail.
Reference: 01-063
Distribution box for 4 modules, white. For safe installation of relays and / or electricity meters for DIN rail. W X H X D = 110 X 180 X 82 mm
Reference: 01-042
Electricity meter Eastron DCM230 Modbus ATTENTION! Supply voltage 230V AC Very advanced electricity meter that has a counter, trip meter (which can be reset), power meter and much more (click "MORE" for full specifications). The electricity meter has an illuminated display, pulse output and connection for modbus RTU communication. Error display less than...
Reference: 01-026
Eastron ESCT-345 3 X 300/1 A Current transformer Can be used with our SDM630MCT V2 electricity meters. Opening för cable 3 pieces 32 X 32 mm 52 X 92 X 152 mm (W x H x L) Weight 0.65 kg
Reference: 01-031
Distribution box 8 modules Premium, white. For safe installation of electricity meters, relays, circuit breakers, earth leakage circuit breaker mm DIN rail.
Reference: 01-062
Split core current transformer 400A / 5A SCT036TS 400/5 A Inner diameter of the coil is 35 mm. Fits our electric meters SDM630 MCT V2 SDM120CTM, SDM120CTMB External dimensions: 49 X 66 X 93 mm Includes 1 pcs (Order 3 pcs for three-phase electricity meters) Accuracy 1%
Reference: 01-069
Brand: Carlo Gavazzi
Carlo Gavazzi EM111-O1 single-phase puls meter Single-phase energy analyzer with backlit LCD display with integrated touch keypad. Particularly indicated for active energy metering and for cost allocation in MID applications up to 45 A (direct connection)
Reference: 01-078
Brand: Carlo Gavazzi
Electricity meter 3-phase Carlo Gavazzi EM330-HS1 Modbus for measuring with current coils Three-phase electricity meter with Modbus for measuring with current coils, model designation: EM330DINAV53HS1PFB for 3-phase (65A/400V). Approved for debit metering, used for net metering/production. Can be logged with Logger 1010 or Logger 3030 PRO Modbus.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
SDM630 Modbus MCT V2 3-phase energy meter. (Non MID)
For use with current transformators (Coils) 50 A and up. We stock 50, 100 and 200 A coils.
Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 3030 datalogger.