Reference: 02-008

Brand: Energibutiken, WebIQ AB

Dallas 1-wire PRO tube surface sensor 5 meter

(0)

Tube surface Sensor, affordable 5 meter 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to the Logger 2020.  This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20

Price SEK 249.00
More
In Stock (13 pcs.)

Reference: 04-013

Brand: Energibutiken, WebIQ AB

Cable 3-wire

(0)

Cable 3-wire Unshielded cable for connection of temp sensors/modules and/or to use as a bus conductor in the system. Area: 3 x 0.14 mm2Color: GraySelect cable length before you add to shopping cart.

Price SEK 8.00
More
In Stock (518 pcs.)

Reference: 01-001

Brand: Eastron

SDM72DR MID Energy Meter with resettable trip counter

(7)

MID certified Threee Phase Energy Meter! MID certified 3-phase electricity meters with both non-resetable counter and resettable trip counter, power meter that shows exactly how many watts that is currently consumed.4 modules wide. For 35 mm DIN rail. Perfect for those who want to monitor the house, cottage, heat pump, or whatever it may be! Need help?...

Price SEK 849.00
More
In Stock (443 pcs.)

Reference: 01-004

Brand: Eastron

Eastron SDM630 Modbus MID V2, 3-phase electricity meter

(0)

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.

Price SEK 1,327.00
More
In stock (343 pcs.)

Reference: 04-012

Brand: Energibutiken, WebIQ AB

Cable 2X0.14 mm2

(0)

Cable 2X0.14 mm2 Unshielded cable for connection of electricity meter sensors, digital input sensors.Area: 2 x 0.14 mm2Color: Gray Select cable length before adding to cart.

Price SEK 6.00
More
In Stock (757 pcs.)

Reference: 25-001

Chint NL210 3-phase residual current device TYPE B

(2)

Chint NL210 3-phase earth leakage circuit breaker TYPE BGround fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.

Price SEK 1,679.00
More
In Stock (112 pcs.)

Reference: 15-001

Brand: Energibutiken, WebIQ AB

Vibration damper Premium

(13)

Vibration dampers Premium "Soft" A kit that we meticulously evaluated and put together to get the best possible way to de-vibrate air heat pumps. This "soft" kit has slightly softer springs than our "hard" kit, especially designed for those who mount in places that are well protected from harsh winds. Our soft package has hardness 5/3 compared to the hard...

Price SEK 754.00
More
In Stock (79 pcs.)
All best sellers
SDM630 M-bus MCT V2 MID 3-phase electricity meter
  • SDM630 M-bus MCT V2 MID 3-phase electricity meter
  • SDM630 Modbus MID 3-phase electricity meter dimensions
  • SDM630 Modbus MID 3-phase electricity meter terminals
  • SDM630 Modbus MID 3-phase electricity meter, other terminals

Eastron SDM630 MCT M-bus V2 MID 3-phase electricity meter

01-029

SDM630 MCT M-bus V2 MID 3-phase energy meter.

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, M-bus communication available suitable for our Logger 3030 datalogger.

MID certification makes it possible to use for billing purposes.

Volume discounts

Quantity Unit discount You Save
5 10% Up to SEK 675.00
SEK 1,350.00
Tax included
Quantity
In stock (46 in stock)

Description

SDM630 MCT M-bus V2 MID 3-phase electricity meter

With M-bus, pulse output suitable for logging.

Modular device for DIN rail 35mm, width: 4 modules (72.3 mm), the display shows Volts, Watts, Apmeres, Frequecy, Power factor and more.

MID certification makes it possible to use for billing purposes.

Specifications

5.1 Measured Parameters

The unit can monitor and display three phase four wire (3p4w) supply.

5.1.1 Voltage and Current

Phase to neutral voltages 100 to 289V a.c.

Voltages between phases 173 to 500V a.c.

Percentage total voltage harmonic distortion (THD%) for each phase to N

Percentage voltage THD% between phases

Current THD% for each phase

Power factor and Frequency and Max. Demand

Frequency in Hz

Instantaneous power:

Power 0 to 3600 MW

Reactive Power 0 to 3600 MW

Volt-amps 0 to 3600 MVA

Maximum demanded power since last Demand reset Power factor

Maximum neutral demand current, since the last Demand reset (for three phase supplies only)

Energy Measurements

Imported active energy 0 to 999999.99 kWh

Exported active energy 0 to 999999.99 kWh

Imported reactive energy 0 to 999999.99 kVArh

Exported reactive energy 0 to 999999.99 kVArh

Total active energy 0 to 999999.99 kWh

Total reactive energy 0 to 999999.99 kVArh

Measured Inputs

Maximum terminal opening for power cables is 2,5 mm2

Accuracy

Voltage 0·5% of range maximum

Current 0·5% of nominal

Frequency 0·2% of mid-frequency

Power factor 1% of unity (0.01)

Active power (W) ±1% of range maximum

Reactive power (VAr) ±1% of range maximum

Apparent power (VA) ±1% of range maximum

Active energy (Wh) Class 1 IEC 62053-21

Reactive energy (VARh) ±1% of range maximum

Total harmonic distortion 1% up to 31st harmonic

Temperature co-efficient Voltage and current = 0.013%/°C typical

Active energy = 0·018%/°C, typical

Response time to step input 1s, typical, to >99% of final reading, at 50 Hz.

Interfaces for External Monitoring

Three interfaces are provided:

M-bus

One fixed pulse output 3200 Imp/kWh

M-bus parameters are configured through the Set-up screens.

Pulse Relay Output

The pulse relay output can be set to generate pulses to represent kWh or kVArh.

Rate can be set to generate 1 pulse per:

0.01 = 10 Wh/VArh

0.1 = 100 Wh/VArh

1 = 1 kWh/kVArh

10 = 10 kWh/kVArh

100 = 100 kWh/kVArh

Pulse width 200/100/60 ms.

Relay Rating 240V ac 50mA

M-bus

For M-bus the parameters can be configured from the

Set-up menu:

Baud rate 2400, 4800, ,9600, ,19200, 38400

Parity none/odd/even

Stop bits 1 or 2

Address 001 to 250

Reference Conditions of Influence Quantities

Influence Quantities are variables that affect measurement errors to a minor degree. Accuracy is

verified under nominal value (within the specified tolerance) of these conditions.

Ambient temperature 23°C ±2°C

Input waveform 50 or 60Hz ±2%

Input waveform Sinusoidal (distortion factor < 0·005)

Auxiliary supply voltage Nominal ±1%

Auxiliary supply frequency Nominal ±1%

Auxiliary supply waveform (if AC) Sinusoidal (distortion factor < 0·05)

Magnetic field of external origin Terrestrial flux

 

Environment

Operating temperature -25°C to +55°C*

Storage temperature -40°C to +70°C*

Relative humidity 0 to 90%, non-condensing

Altitude Up to 3000m

Warm up time 1 minute

Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g

Shock 30g in 3 planes

*Maximum operating and storage temperatures are in the context of typical daily and seasonal

variation.

Mechanics

35 mm DIN rail dimensions 72,3 x 100 mm (WxH) per DIN 43880

Mounting DIN rail (DIN 43880)

Sealing IP51

Material Self-extinguishing UL 94 V-0

Volt, Amps, Power, Power factor and more

MID

2014/32/EU EC certifikat number 0120/SGS0151

Importer and distributor is Web Info Quality EU AB, owner of www.energibutiken.se.

Org. nr, 556787-3756

Product Details
01-029
0
46 Items
Accessories

Reference: 03-015

Brand: Energibutiken, WebIQ AB

Logger 1010

(0)

Logger 1010 'Logger 1010 is a powerful logger / control unit with a focus on being maximally flexible and easy to use. Support for a plethora of sensors, logging locally and remotely, and alarm possibilities via SMS and e-mail, make the areas of use almost endless.

Price SEK 1,099.00
In Stock (189 pcs.)

Reference: 01-040

Current transformers 150 A SCT024TS 150A/5A

(0)

Current transformer 150A / 5A Inner diameter of the coil is 23 X 24 mm. Fits our electric meters SDM630 MCT V2 and Elmätare 3-fas Carlo Gavazzi EM330-HM1 M-bus MID för mätning med strömspolar. . External dimensions: 45 X 41 X 76 mm NOTE! when buying, choose 1 pc for single-phase, 3 pcs for three-phase electricity meters. Accuracy 0.5%

Price SEK 179.00
More
In Stock (293 pcs.)

Reference: 01-058

Current transformers 200 A SCT024TS 200A/5A

(0)

Openable current coils 200A/5A The current coil fits the following electricity meters SDM630 MCT V2 MID, SDM630 MCT V2 non-MID, SDM120D CT-P, SDM120CTM MID, SDM120CTMB M-bus MID, SDM630 MCT M-bus V2 MID. Inner diameter of the coil is 23 X 23 mm. External dimensions: Width 52 X Height 76 X Depth 42 mm 1 piece (Buy 3 pieces for three-phase electricity...

Price SEK 189.00
More
In Stock (76 pcs.)
16 other products in the same category:

Reference: 01-058

Current transformers 200 A SCT024TS 200A/5A

(0)

Openable current coils 200A/5A The current coil fits the following electricity meters SDM630 MCT V2 MID, SDM630 MCT V2 non-MID, SDM120D CT-P, SDM120CTM MID, SDM120CTMB M-bus MID, SDM630 MCT M-bus V2 MID. Inner diameter of the coil is 23 X 23 mm. External dimensions: Width 52 X Height 76 X Depth 42 mm 1 piece (Buy 3 pieces for three-phase electricity...

Price SEK 189.00
More
In Stock (76 pcs.)

Reference: 01-043

Electricity meter single phase DCM 230 modbus

(0)

Electricity meter single phase DCM 230 modbus NOTE! Supply voltage 9-40V DC Electricity meter that have counter, odometer (which can be resetted), instant power meter and more (click on "more" for full specifications). The electricity meter has a litted display, pulse output and connection for Modbus RTU communication. Accuracy better then 1% Backlit...

Price SEK 719.00
More
In Stock (52 pcs.)

Reference: 01-007

Brand: Energibutiken, WebIQ AB

SDM630 M-bus MID 3-phase electricity meter

(0)

SDM630 Mbus MID 3-phase energy meter. Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, Mbus RTU communication available suitable for our Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.

Price SEK 1,327.00
More
In stock (303 pcs.)

Reference: 01-004

Brand: Eastron

Eastron SDM630 Modbus MID V2, 3-phase electricity meter

(0)

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.

Price SEK 1,327.00
More
In stock (343 pcs.)

Reference: 01-040

Current transformers 150 A SCT024TS 150A/5A

(0)

Current transformer 150A / 5A Inner diameter of the coil is 23 X 24 mm. Fits our electric meters SDM630 MCT V2 and Elmätare 3-fas Carlo Gavazzi EM330-HM1 M-bus MID för mätning med strömspolar. . External dimensions: 45 X 41 X 76 mm NOTE! when buying, choose 1 pc for single-phase, 3 pcs for three-phase electricity meters. Accuracy 0.5%

Price SEK 179.00
More
In Stock (293 pcs.)

Reference: 01-064

Brand: Eastron

SDM230-LoRa Mesh

(0)

The SDM230 LoRa Mesh is a new generation single phase multi function energy meter with wireless communication Lora module built inside

Price SEK 699.00
More
In Stock (43 pcs.)

Reference: 01-019

Brand: Hager

Distribution box 6 modules

(0)

Distribution box 6 modules, white. For safe installation of electricity meters, relays, circuit breakers, earth leakage circuit breaker mm DIN rail.

Price SEK 189.00
More
In Stock (18 pcs.)
Comments (0)