SDM630 MCT M-bus V2 MID 3-phase electricity meter

01-029

New

SDM630 MCT M-bus V2 MID 3-phase energy meter.

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, M-bus communication available suitable for our Logger 3030 datalogger.

MID certification makes it possible to use for billing purposes.

More details

91 Items

In stock

1 049,00 kr

Volume discounts

QuantityDiscountYou Save
5 10% Up to 524,50 kr

More info

SDM630 MCT M-bus V2 MID 3-phase electricity meter

With M-bus, pulse output suitable for logging.

Modular device for DIN rail 35mm, width: 4 modules (72.3 mm), the display shows Volts, Watts, Apmeres, Frequecy, Power factor and more.

MID certification makes it possible to use for billing purposes.

Specifications

5.1 Measured Parameters

The unit can monitor and display three phase four wire (3p4w) supply.

5.1.1 Voltage and Current

Phase to neutral voltages 100 to 289V a.c.

Voltages between phases 173 to 500V a.c.

Percentage total voltage harmonic distortion (THD%) for each phase to N

Percentage voltage THD% between phases

Current THD% for each phase

Power factor and Frequency and Max. Demand

Frequency in Hz

Instantaneous power:

Power 0 to 3600 MW

Reactive Power 0 to 3600 MW

Volt-amps 0 to 3600 MVA

Maximum demanded power since last Demand reset Power factor

Maximum neutral demand current, since the last Demand reset (for three phase supplies only)

Energy Measurements

Imported active energy 0 to 999999.99 kWh

Exported active energy 0 to 999999.99 kWh

Imported reactive energy 0 to 999999.99 kVArh

Exported reactive energy 0 to 999999.99 kVArh

Total active energy 0 to 999999.99 kWh

Total reactive energy 0 to 999999.99 kVArh

Measured Inputs

Maximum terminal opening for power cables is 2,5 mm2

Accuracy

Voltage 0·5% of range maximum

Current 0·5% of nominal

Frequency 0·2% of mid-frequency

Power factor 1% of unity (0.01)

Active power (W) ±1% of range maximum

Reactive power (VAr) ±1% of range maximum

Apparent power (VA) ±1% of range maximum

Active energy (Wh) Class 1 IEC 62053-21

Reactive energy (VARh) ±1% of range maximum

Total harmonic distortion 1% up to 31st harmonic

Temperature co-efficient Voltage and current = 0.013%/°C typical

Active energy = 0·018%/°C, typical

Response time to step input 1s, typical, to >99% of final reading, at 50 Hz.

Interfaces for External Monitoring

Three interfaces are provided:

M-bus

One fixed pulse output 3200 Imp/kWh

M-bus parameters are configured through the Set-up screens.

Pulse Relay Output

The pulse relay output can be set to generate pulses to represent kWh or kVArh.

Rate can be set to generate 1 pulse per:

0.01 = 10 Wh/VArh

0.1 = 100 Wh/VArh

1 = 1 kWh/kVArh

10 = 10 kWh/kVArh

100 = 100 kWh/kVArh

Pulse width 200/100/60 ms.

Relay Rating 240V ac 50mA

M-bus

For M-bus the parameters can be configured from the

Set-up menu:

Baud rate 2400, 4800, ,9600, ,19200, 38400

Parity none/odd/even

Stop bits 1 or 2

Address 001 to 250

Reference Conditions of Influence Quantities

Influence Quantities are variables that affect measurement errors to a minor degree. Accuracy is

verified under nominal value (within the specified tolerance) of these conditions.

Ambient temperature 23°C ±2°C

Input waveform 50 or 60Hz ±2%

Input waveform Sinusoidal (distortion factor < 0·005)

Auxiliary supply voltage Nominal ±1%

Auxiliary supply frequency Nominal ±1%

Auxiliary supply waveform (if AC) Sinusoidal (distortion factor < 0·05)

Magnetic field of external origin Terrestrial flux

 

Environment

Operating temperature -25°C to +55°C*

Storage temperature -40°C to +70°C*

Relative humidity 0 to 90%, non-condensing

Altitude Up to 3000m

Warm up time 1 minute

Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g

Shock 30g in 3 planes

*Maximum operating and storage temperatures are in the context of typical daily and seasonal

variation.

Mechanics

35 mm DIN rail dimensions 72,3 x 100 mm (WxH) per DIN 43880

Mounting DIN rail (DIN 43880)

Sealing IP51

Material Self-extinguishing UL 94 V-0

Volt, Amps, Power, Power factor and more

MID

2014/32/EU EC certifikat number 0120/SGS0151

Importer and distributor is Web Info Quality EU AB, owner of www.energibutiken.se.

Org. nr, 556787-3756

Reviews

Write a review

SDM630 MCT M-bus V2 MID 3-phase electricity meter

SDM630 MCT M-bus V2 MID 3-phase electricity meter

SDM630 MCT M-bus V2 MID 3-phase energy meter.

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, M-bus communication available suitable for our Logger 3030 datalogger.

MID certification makes it possible to use for billing purposes.

Write a review

Accessories

Customers who bought this product also bought:

Download