Reference: 02-008

Brand: Energibutiken, WebIQ AB

Dallas 1-wire PRO tube surface sensor 5 meter

(0)

Tube surface Sensor, affordable 5 meter 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to the Logger 2020.  This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20

Price SEK 249.00
More
In Stock (13 pcs.)

Reference: 04-013

Brand: Energibutiken, WebIQ AB

Cable 3-wire

(0)

Cable 3-wire Unshielded cable for connection of temp sensors/modules and/or to use as a bus conductor in the system. Area: 3 x 0.14 mm2Color: GraySelect cable length before you add to shopping cart.

Price SEK 8.00
More
In Stock (518 pcs.)

Reference: 01-001

Brand: Eastron

SDM72DR MID Energy Meter with resettable trip counter

(7)

MID certified Threee Phase Energy Meter! MID certified 3-phase electricity meters with both non-resetable counter and resettable trip counter, power meter that shows exactly how many watts that is currently consumed.4 modules wide. For 35 mm DIN rail. Perfect for those who want to monitor the house, cottage, heat pump, or whatever it may be! Need help?...

Price SEK 849.00
More
In Stock (443 pcs.)

Reference: 01-004

Brand: Eastron

Eastron SDM630 Modbus MID V2, 3-phase electricity meter

(0)

Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.

Price SEK 1,327.00
More
In stock (343 pcs.)

Reference: 04-012

Brand: Energibutiken, WebIQ AB

Cable 2X0.14 mm2

(0)

Cable 2X0.14 mm2 Unshielded cable for connection of electricity meter sensors, digital input sensors.Area: 2 x 0.14 mm2Color: Gray Select cable length before adding to cart.

Price SEK 6.00
More
In Stock (757 pcs.)

Reference: 25-001

Chint NL210 3-phase residual current device TYPE B

(2)

Chint NL210 3-phase earth leakage circuit breaker TYPE BGround fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.

Price SEK 1,679.00
More
In Stock (112 pcs.)

Reference: 15-001

Brand: Energibutiken, WebIQ AB

Vibration damper Premium

(13)

Vibration dampers Premium "Soft" A kit that we meticulously evaluated and put together to get the best possible way to de-vibrate air heat pumps. This "soft" kit has slightly softer springs than our "hard" kit, especially designed for those who mount in places that are well protected from harsh winds. Our soft package has hardness 5/3 compared to the hard...

Price SEK 754.00
More
In Stock (79 pcs.)
All best sellers

Earth fault circuit breaker type B, 40A, 30mA 1-phase (2pol) 4 modules

25-045

Earth fault circuit breaker type B, 40A, 30mA 1-phase (2pol) 4 moduls

CE-marked Earth fault circuit breaker for charging station for electric cars, electric hybrids, charging hybrids. Ground fault circuit interrupter of TYPE B has been a legal requirement since 2017 for charging electric cars. We offer the right switch at an unbeatable price. The earth fault circuit breaker is 4 modules wide. Can be used with fuses between 10 A and 63 A

Volume discounts

Quantity Unit discount You Save
5 SEK 80.00 Up to SEK 400.00
10 SEK 180.00 Up to SEK 1,800.00
SEK 1,199.00
Tax included
Quantity
In Stock (83 in stock)

Description

Earth fault circuit breaker type B, 40A, 30mA 1-phase (2pol) 4 moduls

CE-marked Earth fault circuit breaker for charging station for electric cars, electric hybrids, charging hybrids. Ground fault circuit interrupter of TYPE B has been a requirement since 2017 for charging electric cars. We offer the right switch at an unbeatable price.

RULES

For electric car charging and solar installations, you must have a ground fault circuit interrupter type B according to the new electrical installation rules 2017 (Edition 3 of SS 436 40 00). It is a Swedish standard that should be followed. The reason for this is that an ordinary earth fault circuit breaker can stop working if it is used in these contexts, which in the worst case can lead to fire or electrical accidents.

MORE ABOUT THE RULES

How can it be that there is never any talk of earth fault circuit breakers type B for single-phase wall sockets such as charging hybrids are being charged off?

ANSWER: The new rules from 2017 apply to all new installations, a three-phase charging station is in principle always a new installation and these must then either be equipped with earth fault circuit breakers type B or supplemented with one. previously and the requirements do not apply to these. Our opinion is, however, that there is the same risk of electrical accident, fire or damage to electronic equipment in the property where the outlet is located. Based on this reasoning, it is never wrong to supplement an old socket with a single-phase earth fault circuit breaker type B. We also recommend that you replace old wall sockets with new ones of good quality as old wall sockets can cause loose contact and hot running if they are heavily loaded for a long time.

General information :

  • Rated current: 40A (Can handle all currents up to a maximum of 40A)
  • Voltage: 230 / 400VAC ~ 240 / 415VAC
  • Short-circuit breaking capacity: 10kA IEC / EN 62423 & IEC / EN 61008-1
  • CE marked: Yes
  • Number of poles: 4P (takes up 4 modules width)
  • Type: B
  • Enclosure class: IP20
  • DIN connection: 4 modules wide
  • Mechanical service life: 4000 connections
  • Electrical life: 4000 connections
  • Operating temperature: -25… + 40˚C with an ambient temperature of 35˚C

Type Description:

B-Class (Type B): Standard protection. Mainly developed to protect systems with DC applications. Provides extended protection in direct and sinusoidal DC applications

Product Details
25-045
0
83 Items
13 other products in the same category:

Reference: 25-001

Chint NL210 3-phase residual current device TYPE B

(2)

Chint NL210 3-phase earth leakage circuit breaker TYPE BGround fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.

Price SEK 1,679.00
More
In Stock (112 pcs.)

Reference: 25-029

Main switch / Load switch

(0)

Main switch / Load switch Intended as an incoming circuit breaker in standard power stations (power plant). The main switch can be locked in the off position with a standard padlock.

Price SEK 182.00
More
In Stock (225 pcs.)

Reference: 25-030

Sofielec JVL 16-63, 300 mA 3-phase residual current device TYPE B

(0)

Sofielec JVL 16-63, 3-phase earth leakage circuit breaker TYPE B 300 mA for machine and fire protection.Ground fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits...

Price SEK 1,799.00
More
In Stock (101 pcs.)

Reference: 26-001

Power supply for electric car charging station

(0)

Electric box for charging stations Complete power supply for charging stations to electric cars and charging hybrids 10-63A (Select in the drop-down list).Contains Electricity Meter SDM630 Modbus MID, Chint NL210 3-phase earth leakage circuit breaker TYP B and three-phase automatic circuit breaker 10-63A.

Price SEK 2,814.00
In Stock (39 pcs.)

Reference: 26-030

Vägguttag 2-vägs

(1)

Wall socket 2-way earthed IP44 Approved according to the insurance companies' requirements for installation in agriculture. The plastic has very good properties compared to vegetable oils and ammonia. screw connection Polar white.

Price SEK 239.00
More
In Stock (10 pcs.)

Reference: 25-041

Brand: Chint

Chint NL210 3-phase residual current device TYPE B

(0)

Chint NL210 3-phase earth leakage circuit breaker TYPE B Ground fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.

Price SEK 1,895.00
More
In Stock (36 pcs.)

Reference: 25-044

copy of Main switch / Load switch

(0)

Main switch / Load switch Intended as an incoming circuit breaker in standard power stations (power plant). The main switch can be locked in the off position with a standard padlock.

Price SEK 149.00
More
In Stock (14 pcs.)

Reference: 26-002

Power supply for charging station

(1)

Electric box for charging stations Complete power supply for charging stations to electric cars and charging hybrids 10-63A (Select in the drop-down list).Contains Electricity Meter SDM72DR, Chint NL210 3-phase earth leakage circuit breaker TYP B and three-phase automatic circuit breaker 10-63A.

Price SEK 2,485.00
In Stock (50 pcs.)

Reference: 26-003

Power supply for charging station

(0)

Electric box for charging stations Complete power supply for charging stations to electric cars and charging hybrids 10-63A (Select in the drop-down list).Contains Electricity Meter SDM230DR, Chint NL210 1-phase earth leakage circuit breaker TYP B and singel-phase automatic circuit breaker 10-63A.

Price SEK 1,895.00
In Stock (7 pcs.)

Reference: 25-040

Jordfelsbrytare Typ B 40A 30mA - 3P (4-Pol)

(0)

Sofielec 3-phase earth fault circuit breaker TYPE B CE-marked Earth fault circuit breaker for charging station for electric cars, electric hybrids, charging hybrids or photovoltaic systems. Ground fault circuit interrupter of TYPE B has been a requirement since 2017 for charging electric cars and in photovoltaic systems. We offer the right switch at an...

Price SEK 1,499.00
More
In Stock (19 pcs.)
Comments (0)