- New product

Reference: 02-008
Brand: Energibutiken, WebIQ AB
Tube surface Sensor, affordable 5 meter 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to the Logger 2020. This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20
Reference: 01-009
Brand: Eastron
Eastron SDM120D MID single phase meter Affordable electricity meter with both flashing diode and pulse output with 1000 imp / kWh. One module wide.
Reference: 04-013
Brand: Energibutiken, WebIQ AB
Cable 3-wire Unshielded cable for connection of temp sensors/modules and/or to use as a bus conductor in the system. Area: 3 x 0.14 mm2Color: GraySelect cable length before you add to shopping cart.
Reference: 01-001
Brand: Eastron
MID certified Threee Phase Energy Meter! MID certified 3-phase electricity meters with both non-resetable counter and resettable trip counter, power meter that shows exactly how many watts that is currently consumed.4 modules wide. For 35 mm DIN rail. Perfect for those who want to monitor the house, cottage, heat pump, or whatever it may be! Need help?...
Reference: 01-004
Brand: Eastron
Modular device for DIN rail 35mm, width: 4 modules, the display shows Volt, Amps, Power, Power factor and more. With pulse output suitable for logging, modbus RTU communication available suitable for our Logger 1010 or Logger 3030 datalogger. MID certification makes it possible to use for billing purposes.
Reference: 04-012
Brand: Energibutiken, WebIQ AB
Cable 2X0.14 mm2 Unshielded cable for connection of electricity meter sensors, digital input sensors.Area: 2 x 0.14 mm2Color: Gray Select cable length before adding to cart.
Reference: 25-001
Chint NL210 3-phase earth leakage circuit breaker TYPE B Ground fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.
Reference: 02-033
Brand: Energibutiken, WebIQ AB
Hose clamp for fastening Pipe wrap probe Fits Pipe wrap probe Dallas 1 PRO and PT1000 and PT100 Pipe wrap probe. Takes pipes up to 100 mm diameter.
Reference: 02-006
Brand: Energibutiken, WebIQ AB
Tube surface Sensor, affordable 3-wire temperature sensor with the sensor encapsulated in a 14 mm polished "prism" aluminium casing, the sensors are specially adapted to Logger 2020. This type of temperature sensor are very accurate, calibrated in the factory. Chip: Dallas DS18B20
Reference: 15-001
Brand: Energibutiken, WebIQ AB
Vibration dampers Premium "Soft" A kit that we meticulously evaluated and put together to get the best possible way to de-vibrate air heat pumps. This "soft" kit has slightly softer springs than our "hard" kit, especially designed for those who mount in places that are well protected from harsh winds. Our soft package has hardness 5/3 compared to the hard...
Garo safety switches can handle 16A and have a 2-pole connection, this product is available in white with a black knob. The outer screws are made of stainless steel. The seal between box and lid is a weather- and oil-resistant gasket made of chloroprene rubber, which means that it is IP65 and suitable both indoors and outdoors.
Garo safety switches can handle 16A and have a 2-pole connection, this product is available in white with a black knob. The outer screws are made of stainless steel. The seal between box and lid is a weather- and oil-resistant gasket made of chloroprene rubber, which means that it is IP65 and suitable both indoors and outdoors.
The cable entries are threaded and have knockouts for 2 parallel cables both at the top and bottom. The knob is lockable with a padlock and the lid is locked in the closed position. There are neutral and PE connections in the enclosure.
According to ELSÄKERHETSVERKET's High Current regulations, all new installations of e.g. Air source heat pumps or other permanently installed machines should be equipped with a Safety Switch.
C62.2 Separation The plant part on which work is to be carried out must be separated. Components that are still live after separation, for example capacitors and cables, must be discharged with a suitable device. Advice: Where the power supply can take place from several directions or when there are several electrical switches, special care is required to prevent mistakes. Among other things, all windings need to be separated when working on the transformer. The magnetizing circuits of machines and the neutral point that is not directly grounded must be isolated if voltage can be applied from another part of the installation. In order to achieve the necessary safety, separation should take place in one of the following ways: 1.3 Use of safety switches.
ATTENTION! Only 1-phase safety switch with earth and neutral terminal.
Dimensions
Width: 115 mm
Height: 137 mm
Depth: 60 mm
Weight: 0.29 kg
Technical data
Version as service/repair switch: Yes
Version as safety switch: Yes
Max rated operating voltage Ue at AC: 690 V
Nominal operating voltage: 400...690 V
Nominal continuous current Iu:16 A
Conditional nominal short-circuit current Iq: 25 kA
Number of poles: 2
Device construction method: Complete device in enclosure
Suitable for four-hole front mounting: Yes
Suitable for central front mounting: Yes
Suitable for installation in distributions: Yes
Suitable for intermediate assembly: Yes
Color of operating element: Black
Type of control element: Rocker
Can be blocked: Yes
Main circuit connection method: Cable clamp
Protection class (IP), front: IP65
Protection Level (NEMA)
Reference: 04-025
Brand: Energibutiken, WebIQ AB
12 Volt relay module for Logger 1010 & Logger 3030. Relay module: For connection to the digital outputs of Logger 1010 or Logger 3030. Can also be used in combination with one of our contactors for three-phase loads and/or for single-phase currents above 8A. Primary: 12 V dc, 0.5 W Secondary: 230 V ac, max 8 A.
Reference: 26-038
Safety switch The enclosure of the ABB´s side controlled enclosed switches is made of rigid polycarbonate. The enclosure is UV protected, and protected against low pressure water jets (IP65), and hence built for outdoor and indoor use.
Reference: 03-014
Smart electrical outlet with temperature sensor 16A GSMA smart product for you who want to be able to remotely control different products to a bit remote places. Suitable for you who want to be able to control the element on the cottage via an app or a simple text message, it can also be used for controlling lamps and AC units.
Reference: 25-040
Sofielec 3-phase earth fault circuit breaker TYPE B CE-marked Earth fault circuit breaker for charging station for electric cars, electric hybrids, charging hybrids or photovoltaic systems. Ground fault circuit interrupter of TYPE B has been a requirement since 2017 for charging electric cars and in photovoltaic systems. We offer the right switch at an...
Reference: 27-001
Earth fault switch 4P, 40A, 30mA Type A Standard earth fault switch for personal protection 30 mA, three phase max 40A.
Reference: 25-024
3-phase Personal protection switch / personal protection automatic 4-pole Personal protection circuit breaker is a combination of earth fault circuit breaker and miniature circuit breaker, ie it protects against both earth faults and overcurrent. The circuit breaker / personal protection machine has a total of 4 poles, ie 3 poles + N.
Reference: 26-030
Wall socket 2-way earthed IP44 Approved according to the insurance companies' requirements for installation in agriculture. The plastic has very good properties compared to vegetable oils and ammonia. screw connection Polar white.
Reference: 25-034
Distribution Box 13 Modules A distribution box for you who are constucting new buldings och renovating old buildings. The distribution box is suitable for: Garage 'Storehouse Workshop Holiday home Cottages Sheds Warehouses Machine halls,
Reference: 25-001
Chint NL210 3-phase earth leakage circuit breaker TYPE B Ground fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYP B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall.
Reference: 25-029
Main switch / Load switch Intended as an incoming circuit breaker in standard power stations (power plant). The main switch can be locked in the off position with a standard padlock.
Garo safety switches can handle 16A and have a 2-pole connection, this product is available in white with a black knob. The outer screws are made of stainless steel. The seal between box and lid is a weather- and oil-resistant gasket made of chloroprene rubber, which means that it is IP65 and suitable both indoors and outdoors.